Cloud Tunnel
The wendy cloud tunnel command forwards a local TCP or UDP port to an authorized service on a cloud-enrolled device.
Cloud Tunnel
The wendy cloud tunnel command forwards a local TCP or UDP port to an authorized
service on a cloud-enrolled device. Cloud v2 authorizes each port through its
service catalog; legacy sessions use the legacy broker. It listens on
127.0.0.1 on your development machine and reaches the remote service through
the Cloud broker. Start with the
Cloud v2 or Legacy tab if you have not selected a session yet.
Prerequisites
- Authenticated with the intended Cloud context. Use
wendy cloud loginfor v2, orwendy cloud login --legacyfor v1, then checkwendy cloud status. - At least one compute device enrolled and online in your organization.
Usage
wendy cloud tunnel [<local-port>:<remote-port>[/udp]] [--cloud-grpc <endpoint>] [--device <id|name>]Without a port mapping, the command prompts for one in a terminal. Scripts
and --json invocations must pass the mapping.
For example, forward local port 15052 to the Wendy Agent service:
wendy cloud tunnel 15052:50052 --device shop-floor-01This is a transport for an authenticated Agent client, not an HTTP endpoint. Forwarding does not bypass the Agent's authentication. Keep the command running while using it, then press Ctrl+C to close the forward.
Without a protocol suffix, the command uses TCP. Append /udp to forward UDP
datagrams. A single port uses that port at both ends.
Cloud v2 supports any TCP or UDP port from 1 through 65535 on the device's loopback interface. For example:
wendy cloud tunnel 8080:3007 --device shop-floor-01
wendy cloud tunnel 9000:9000/udp --device shop-floor-01Arbitrary ports require an updated Cloud service, plus CLI and agent 2026.10.22-211023 or newer. Older v2 versions support only TCP ports 22 and 50052. Legacy sessions retain their existing TCP and UDP forwarding behavior.
Each v2 UDP session authorizes one remote port. Separate local peers use separate flows, with up to 64 active flows and 16 new flows per second. Empty datagrams are supported; the maximum payload is 65507 bytes.
Port 22 requires an SSH server on the target. Release Jetson and Raspberry Pi images do not
include one; listing ssh in the catalog does not make SSH available there.
Before moving a custom application port or UDP workflow from v1, test it on v2
with the updated versions. See Moving to Cloud v2.
The CLI:
- Lists the online compute devices enrolled in your organization, up to a cap of 10,000 devices. If more are returned, the command exits with an error:
cloud returned more than 10000 devices. - Selects the target device:
- When
--deviceis set, matches it against device names (case-insensitive exact match). On a legacy session a plain integer is also accepted as the numeric asset ID, which is how devices enrolled without a name are reached; on a cloud (OIDC) session there is no numeric fallback — pass the device's name or its UUID. - When
--deviceis unset and exactly one device is online, connects to it directly. - When
--deviceis unset and more than one device is online:- In an interactive terminal, presents the cloud discover TUI in picker mode (
↑/↓to navigate,enterto select,uto update a device before connecting,qto cancel). - In a non-interactive environment, exits with an error that enumerates available devices as
id=namepairs (unnamed devices show as(unnamed)). Pass--device <id|name>to select one directly.
- In an interactive terminal, presents the cloud discover TUI in picker mode (
- When
- Starts the local listener and forwards traffic to the requested port on the selected device.
Only online devices are shown. To inspect enrolled but offline devices, use
wendy cloud discover --all.
Use wendy cloud discover --json to obtain selectors: UUIDs for Cloud v2,
numeric asset IDs for legacy Cloud, or device names in either environment.
Reconnection and app uploads
For app uploads over Cloud v2,
a lost connection reports the device and upload progress across resume attempts.
Devices without a display name are identified by their Cloud ID. A failed upload
reconnect, or a connection loss while waiting for the app's start acknowledgement,
reports a retryable device_unreachable failure (exit 5). Check that the device
is online with wendy cloud discover, then retry. Automatic registry fallback
is off after that transport failure. --chunking=off selects an explicit registry
upload with the usual authorization. In auto, old Agents without the chunk
RPCs retain their existing registry fallback.
Device updates and legacy Cloud resume keep their existing restart-wait messages.
Flags
| Flag | Description |
|---|---|
--cloud-grpc | Override the cloud gRPC endpoint. Overrides session selection. When multiple sessions are stored and no default is set, an interactive terminal shows a session picker; a non-interactive environment errors. |
--device | Target a specific device by name (case-insensitive exact match), by UUID, or — on legacy sessions only — by numeric asset ID. When omitted in a non-interactive context with multiple devices, the command exits with an error listing id=name pairs. |
--broker-url | Override the tunnel broker host and port. Legacy sessions only; defaults to WENDY_BROKER_URL when set, otherwise the cloud endpoint's broker address. On a cloud (OIDC) session Cloud selects the authorized relay and passing this flag errors. |