WendyOS Docs
Wendy CLIclouddevicecamera

wendy cloud device camera set-control

Set tunable controls on a local camera

Syntax

wendy cloud device camera set-control <id> name=value [name=value ...] [flags]

Examples

wendy cloud device camera set-control --help

Arguments

Argument notation from the CLI: <id> name=value [name=value ...]. Angle brackets mark required values; square brackets mark optional values. See Details for command-specific validation.

Flags

Flags below include inherited options. Types and defaults come from the CLI source. An empty default means no value is configured.

FlagTypeDefaultDescription
--broker-urlstring(empty)Tunnel broker host:port (default: cloud :443 endpoint, otherwise <cloud-host>:50052)
--cloud-grpcstring(empty)Cloud gRPC endpoint (optional when a default session is set via 'wendy auth use')
--devicestring(empty)Target device hostname; wendy run accepts a comma-separated list to deploy one build to several devices (needs a remote build host and --detach). Defaults to $WENDY_DEVICE, then the saved default device
--jsonboolfalseOutput in JSON format
--no-persistboolfalseApply once now; do not re-apply on stream reconnect or reboot
--resetstringSlice[]Put these controls back to the driver's default and stop persisting them
--reset-allboolfalsePut every mutable control back to the driver's default and forget them all

Output

Output depends on the operation and selected target. Use the command help for additional guidance..

JSON output

The global --json option requests machine-readable output. The CLI also selects JSON mode when no interactive terminal is attached. Support and payloads are command-specific; this flag does not guarantee a single JSON document for commands that stream logs or invoke build tools. Consult Details before parsing command output.

Exit codes

The CLI entry point returns 0 on success and for its user-cancelled or default-cleared results. Other returned errors exit with 1 and print a diagnostic to stderr. Some operations may terminate through subprocess or signal handling; do not infer application health from the CLI exit code alone.

Common errors

Check argument values and flag combinations against the synopsis above. For discovery, build, port, and readiness failures, see deployment troubleshooting. Command-specific constraints are in Details.

See also

Details

Set tunable V4L2 controls on a local (USB/CSI) camera.

Controls are given as name=value pairs and applied in a safe order (a mode control such as auto_exposure lands before the control it enables). Values persist across stream reconnects and reboots unless --no-persist is given.

Example -- stop a flame or lamp from blowing out to white by forcing a short manual exposure:

wendy device camera set-control 0 auto_exposure=1 exposure_time_absolute=20 backlight_compensation=0

Run "wendy device camera controls <id>" first to see the available controls and their ranges.

To undo: --reset puts named controls back to the driver's default and stops persisting them, and --reset-all does that for every mutable control:

wendy device camera set-control 0 --reset auto_exposure,exposure_time_absolute wendy device camera set-control 0 --reset-all

Use the command help for additional guidance.

On this page